LPP2: Site Allocations and Development Management Policies

Appendix I

Technical Housing Standards - Nationally Described Space Standards

The standard[1] requires that:

  1. 'The dwelling provides at least the gross internal floor area and built-in storage area set out in the Table below;
  2. A dwelling with two or more bed spaces has at least one double (or twin) bedroom ;
  3. In order to provide one bed space, a single bedroom has a floor area of at least 7.5m2 and is at least 2.15m wide;
  4. In order to provide two bed spaces, a double (or twin bedroom) has a floor area of least 11.5m2;
  5. One double (or twin bedroom) is at least 2.75m wide and every other double (or twin) bedroom is at least 2.55m wide;
  6. Any area with a headroom of less than 1.5m is not counted within the Gross Internal Area unless used solely for storage (if the area under the stairs is to be used for storage, assume a general floor area of 1m2 within the Gross Internal Area);
  7. Any other area that is solely for storage and has a headroom of 900-1500mm (such as under eaves) is counted at 50% of its floor area, and any lower area lower than 900mm is not counted at all;
  8. A built-in wardrobe counts towards the Gross Internal Area and bedroom floor requirements, but should not reduce the effective width of the room below the minimum widths set out above. The built-in area in excess of 0.72m2 in a double bedroom and 0.36m2 in a single bedroom counts towards the built-in storage requirement;
  9. The minimum floor to ceiling height is 2.3m for at least 75% of the Gross Internal Area'.

Table 5: Minimum gross internal floor areas and storage (m2)

Number of bedrooms (b)

Number of bed spaces (persons)

1 storey dwellings

2 story dwellings

3 storey dwellings

Built-in storage

1b

1p

39 (37) *

   

1

2p

50

58

 

1.5

2b

3p

61

70

 

2

4p

70

79

 

3b

4p

74

84

90

2.5

5p

86

93

99

6p

95

102

108

4b

5p

90

97

103

3

6p

99

106

112

7p

108

115

121

8p

117

124

130

5b

6p

103

110

116

3.5

7p

112

119

125

8p

121

128

134

6b

7p

116

123

129

4

8p

125

132

138

Notes (added 19 May 2016):

1. Built-in storage areas are included within the overall GIAs and include an allowance of 0.5m² for fixed services or equipment such as a hot water cylinder, boiler or heat exchanger.

2. GIAs for one storey dwellings include enough space for one bathroom and one additional WC (or shower room) in dwellings with 5 or more bed spaces. GIAs for two and three storey dwellings include enough space for one bathroom and one additional WC (or shower room). Additional sanitary facilities may be included without increasing the GIA provided that all aspects of the space standard have been met.

3. Where a one bedroom one person (1b1p) has a shower room instead of a bathroom, the floor area may be reduced from 39m² to 37m², as shown bracketed.

4. Furnished layouts are not required to demonstrate compliance.

1. Technical housing standards – nationally described space standard (March 2015 – updated 19 May 2016) by the Department for Communities and Local Government. Available at https://www.gov.uk/government/publications/technical-housing-standards-nationally-described-space-standard [back]